Why a 2x4 is not 2 by 4 inches
The name is the nominal size: roughly the size of the board when it is first sawn from the log. The board is then dried, which shrinks it, and planed smooth on all four sides, which takes off a bit more. What reaches the store is about half an inch smaller in each direction. The finished sizes are fixed by the American Softwood Lumber Standard, so a kiln-dried 2x4 from any US or Canadian mill should measure the same.
Length works differently. An 8 ft 2x4 is cut to at least 8 ft, often a fraction over. Only the thickness and width shrink to their "dressed" sizes.
Nominal vs actual lumber size chart
| Nominal | Actual (dry, surfaced) | Metric |
|---|---|---|
| 1x4 | 3/4 × 3-1/2 in | 19 × 89 mm |
| 1x6 | 3/4 × 5-1/2 in | 19 × 140 mm |
| 2x3 | 1-1/2 × 2-1/2 in | 38 × 64 mm |
| 2x4 | 1-1/2 × 3-1/2 in | 38 × 89 mm |
| 2x6 | 1-1/2 × 5-1/2 in | 38 × 140 mm |
| 2x8 | 1-1/2 × 7-1/4 in | 38 × 184 mm |
| 2x10 | 1-1/2 × 9-1/4 in | 38 × 235 mm |
| 2x12 | 1-1/2 × 11-1/4 in | 38 × 286 mm |
| 4x4 | 3-1/2 × 3-1/2 in | 89 × 89 mm |
| 4x6 | 3-1/2 × 5-1/2 in | 89 × 140 mm |
| 6x6 | 5-1/2 × 5-1/2 in | 140 × 140 mm |
The pattern is easy to remember for 2x and thicker lumber: each dimension up to 6 in nominal loses 1/2 in, and widths of 8 in and more lose 3/4 in. Boards sold as 1x are the exception in thickness: they are 3/4 in thick, not 1/2 in. Canadian yards use the same names, and metric labels such as 38 × 89 are simply the actual 2x4 size in millimeters.
In Australia, seasoned pine framing is sold by its actual size, commonly 90 × 45, 90 × 35 or 70 × 35 mm, although many builders still call a 90 × 45 stud a "4x2", width first. Green (unseasoned) hardwood is a different case: it is often sold by its sawn size, such as 100 × 50 mm, and shrinks as it dries, so the finished piece is smaller than the label.
Common stock lengths for a 2x4 are 8, 10, 12, 14 and 16 ft, with 18 and 20 ft at larger yards. Precut studs, covered below, are the other common length.
A few exceptions are worth knowing. Lumber surfaced while still green is left slightly fuller (a green 2x4 is about 1-9/16 × 3-9/16 in) because it will shrink as it dries. Pressure-treated boards are often wet when you buy them and can shrink a little after they go in. Rough-sawn lumber from a small sawmill may be close to its full nominal size. Older houses are another surprise: today's 1-1/2 × 3-1/2 in size became standard in the 1960s, and studs in houses built before then are often thicker, around 1-5/8 × 3-5/8 in, or a full 2 × 4 in when the wood was rough-sawn. When you add onto an old wall, measure the existing studs and shim the new ones to match. Measure before you cut anything that must fit tightly.
What size are wall studs?
In US and Canadian houses, wall studs are almost always 2x4 or 2x6. Interior partitions are usually 2x4. Exterior walls are 2x4 in many older and warm-climate homes and 2x6 in much newer construction, especially in cold climates. Spacing is normally 16 in on center, sometimes 24 in; the stud spacing guide covers how to find them in an existing wall.
Studs are sold in two kinds of lengths: ordinary stock lengths (8, 10, 12 ft and so on) and precut lengths made to give a standard ceiling height once the plates are added.
| Precut stud | Framed wall height (1 bottom + 2 top plates) | Finished ceiling |
|---|---|---|
| 92-5/8 in | 97-1/8 in | 8 ft |
| 104-5/8 in | 109-1/8 in | 9 ft |
| 116-5/8 in | 121-1/8 in | 10 ft |
Each plate adds 1-1/2 in, so three plates add 4-1/2 in. The extra 1-1/8 in above the even foot leaves room for ceiling drywall and floor finishes. The 116-5/8 in size is not stocked everywhere; ask your yard.
Worked example: cutting studs for a basement wall
You are framing a 12 ft partition in a basement. Measured in several spots, the lowest distance from the slab to the underside of the floor joists is 94-1/4 in. With one bottom plate and a doubled top plate:
stud length = 94-1/4 in − (3 × 1-1/2 in) = 94-1/4 − 4-1/2 = 89-3/4 in
A 92-5/8 in precut is 2-7/8 in too long, so buy precuts and trim each one, rather than cutting 8 ft boards and wasting about 6 in per stud. Measure at each stud location if the slab or joists are uneven, and use pressure-treated lumber for the bottom plate on concrete, as codes generally require.
For the count, the stud calculator with a 12 ft wall at 16 in on center, 1 in the "Corners and wall junctions" box, one door opening and 10 percent extra gives 10 layout studs, 4 extra for the junction and door, and 16 studs to buy, plus 36 linear feet of plate: three 12 ft boards.
2x4 vs 2x6 walls
| 2x4 wall | 2x6 wall | |
|---|---|---|
| Framing depth | 3-1/2 in (89 mm) | 5-1/2 in (140 mm) |
| With 1/2 in drywall both sides | 4-1/2 in (114 mm) | 6-1/2 in (165 mm) |
| Exterior: 7/16 in sheathing + 1/2 in drywall, before siding | 4-7/16 in | 6-7/16 in |
| Batt insulation made for the cavity | R-13 or R-15 | R-19, R-20 or R-21 |
Standard R-19 batts are a little thicker than 5-1/2 in and lose some R-value when squeezed into a 2x6 cavity; R-20 and R-21 batts are made to fit. Energy codes set the minimum. Under the 2021 IECC, R-13 in a 2x4 cavity meets only the warmest climate zones (1 and 2). Zone 3 calls for R-20 in the cavity, which with batts takes a 2x6 wall, or R-13 plus R-5 of continuous insulation outside the sheathing. Zones 4 and colder ask for R-30 in the cavity, R-20 plus R-5 continuous, or R-13 plus R-10 continuous, so even a 2x6 wall there usually needs foam or another insulated sheathing outside. States and cities adopt code editions at different times, so check which one applies to you. The insulation calculator helps with batt counts.
The deeper wall costs a little floor space. On a house measuring 30 × 40 ft outside, switching from 2x4 to 2x6 exterior walls makes each wall 2 in thicker, so the inside loses 4 in in each direction. On the 360 × 480 in footprint that is 360 × 480 − 356 × 476 = 3,344 sq in, or about 23 sq ft less floor area. A 2x6 wall also gives more room for plumbing drains and deeper electrical boxes, which is why a "wet wall" behind a bathroom is often framed with 2x6 even when the rest of the house is 2x4.
To compare what you pay for the extra wood, the board foot calculator shows that an 8 ft 2x6 holds 8 board feet against 5.33 for a 2x4.
Code and safety notes
- Stud size, spacing and height for load-bearing walls are set by code; in the US that is the IRC stud table. A 2x4 bearing wall may be spaced 24 in on center when it carries only a roof and ceiling, but only 16 in when it also carries one floor. Under two floors plus a roof the table does not allow 2x4 studs at all; 2x6 at 16 in is the usual choice. A 2x4 bearing wall is also limited to 10 ft tall without lateral support. Get a permit for structural work.
- Pipes and wires through studs have limits too. Under the IRC, a notch may take up to 25 percent of a bearing stud's width (40 percent in a partition), and a bored hole up to 40 percent (60 percent in a partition), with its edge at least 5/8 in from the face of the stud. On a 2x4 bearing stud that means a hole no bigger than about 1-3/8 in. Where a hole comes within 1-1/4 in of the face, cover the stud with a steel nail plate so drywall screws cannot reach the pipe or cable.
- Wear eye protection when cutting, and a dust mask when cutting pressure-treated lumber.
Sources and standards
- American Softwood Lumber Standard, Voluntary Product Standard PS 20 (dressed lumber sizes)
- International Residential Code (IRC) 2021, Table R602.3(5), stud size, height and spacing
- IRC 2021, Section R602.6, drilling and notching of studs
- International Energy Conservation Code (IECC) 2021, Table R402.1.3, insulation by climate zone
Codes are adopted and amended locally, so the edition and rules that apply to your project are set by your building department.
Frequently asked questions
What is the actual size of a 2x4?
A kiln-dried 2x4 measures 1-1/2 × 3-1/2 in, or 38 × 89 mm. The length is the full nominal length, such as 8 ft, often with a small allowance over.
How long is a precut stud?
92-5/8 in for an 8 ft ceiling and 104-5/8 in for a 9 ft ceiling. With one bottom plate and two top plates, they frame walls 97-1/8 in and 109-1/8 in tall. A 116-5/8 in stud is made for 10 ft ceilings.
What is the actual size of a 2x6?
1-1/2 × 5-1/2 in, or 38 × 140 mm. With 1/2 in drywall on both sides, a 2x6 wall is 6-1/2 in thick, compared with 4-1/2 in for a 2x4 wall.
Do the math for your own project.
Open the stud calculator