Start with your bill, not your roof
Solar sizing begins with how much electricity you use. Find the kWh figure on each bill for the last 12 months, add them up and divide by 12. One month is not enough: a summer bill with the air conditioner running or a winter bill with electric heat can be double your average. If you plan to add an electric vehicle, a heat pump or an electric water heater, add their expected use now. The electricity cost calculator and the heat pump cost calculator can estimate those kWh.
The second number is peak sun hours. It is not the hours of daylight. It is the day's solar energy expressed as hours of full-strength sun (1,000 watts per square meter). A location that gets 4.5 kWh per square meter on an average day has 4.5 peak sun hours. In the continental US, yearly averages on a well-tilted panel run from roughly 3.5 in cloudy northern areas to 6 or more in the desert Southwest.
How the calculator works
daily energy (kWh) = monthly kWh × 12 ÷ 365 × share to cover
system size (kW) = daily energy ÷ (peak sun hours × (1 − losses))
panels = system size × 1,000 ÷ panel watts, rounded up
A panel's watt rating is measured under lab conditions. On a roof, some power is lost to heat, wiring, the inverter, dust and a little shade. The losses setting covers all of that. Planners often use about 20%; NREL's PVWatts tool starts from a default of 14% plus a separate inverter loss, which lands in the same range.
Worked example: 900 kWh a month
A household averages 900 kWh a month, lives where the yearly average is 4.5 peak sun hours, and is pricing 400 W panels with 20% losses.
| Step | Math | Result |
|---|---|---|
| Yearly use | 900 × 12 | 10,800 kWh |
| Daily energy | 10,800 ÷ 365 | 29.6 kWh |
| Output of 1 kW of panels per day | 4.5 × 0.80 | 3.6 kWh |
| System size | 29.6 ÷ 3.6 | 8.22 kW |
| Panels | 8,220 ÷ 400 = 20.6, round up | 21 panels (8.4 kW) |
| Panel area | 21 × 21 sq ft | 441 sq ft (41 m²) |
Rounding up to whole panels gives a little extra: 8.4 kW should produce about 11,038 kWh a year, 102% of the yearly use. Swap in 450 W panels and you need 19 of them (8.55 kW). Cover only 80% of your use and 17 of the 400 W panels do it.
Panels needed by monthly use and sunshine
All rows use 400 W panels and 20% losses. Notice how much the sunshine column matters: the same bill needs roughly 1.5 times as many panels at 3.5 sun hours as at 5.5.
| Monthly use | 3.5 sun hours | 4.5 sun hours | 5.5 sun hours |
|---|---|---|---|
| 500 kWh | 15 panels (6 kW) | 12 panels (4.8 kW) | 10 panels (4 kW) |
| 750 kWh | 23 panels (9.2 kW) | 18 panels (7.2 kW) | 15 panels (6 kW) |
| 1,000 kWh | 30 panels (12 kW) | 23 panels (9.2 kW) | 19 panels (7.6 kW) |
| 1,250 kWh | 37 panels (14.8 kW) | 29 panels (11.6 kW) | 24 panels (9.6 kW) |
| 1,500 kWh | 45 panels (18 kW) | 35 panels (14 kW) | 29 panels (11.6 kW) |
Per panel, a 400 W module with 20% losses makes about 1.12 kWh a day at 3.5 sun hours, 1.44 kWh at 4.5 and 1.76 kWh at 5.5, or roughly 34, 44 and 54 kWh in an average month.
Practical tips
- Get a site-specific number. NREL's PVWatts calculator (free, US-focused but with worldwide weather data) estimates monthly output for your address, roof tilt and direction. Use it to check the peak sun hours you picked here.
- Roof direction counts. In the Northern Hemisphere, south-facing roofs produce the most; east and west faces produce less, and north faces are usually poor. In Australia it is the reverse: north faces are best.
- Leave room around the array. The panel area above is panels only. Fire-code access paths, vents, chimneys and shade from trees cut usable space, so measure the roof faces first with the roofing calculator.
- Bigger is not always better. Net metering and export credit rules vary by utility, and some cap system size at your past use. Ask how exported power is credited before you size past 100%.
- Plan for winter. Short days mean low output in December and January. Snow sliding off the array also loads the eaves below; see the snow load calculator.
Safety and code notes
- Roof work is a fall hazard. Use proper fall protection, or leave rooftop work to a trained crew.
- Panels produce dangerous DC voltage whenever light hits them, even with the main breaker off. Wiring, inverters and grid connection are electrician work.
- Grid-tied systems need a permit and the utility's approval to interconnect. US systems follow the National Electrical Code, including rapid-shutdown rules for rooftop arrays. In Australia, use an accredited designer and installer; rebates through small-scale technology certificates depend on it. Check local code.
- Have an older roof or an unusual roof structure checked before adding the weight of racking and panels.
Frequently asked questions
How many solar panels do I need for 1,000 kWh a month?
With 400 W panels and 20% losses, about 23 panels (9.2 kW) at 4.5 peak sun hours. At 3.5 sun hours it takes about 30 panels (12 kW); at 5.5 sun hours, about 19 panels (7.6 kW).
How much electricity does a 400-watt solar panel produce?
Multiply 0.4 kW by your peak sun hours and by 1 minus losses. At 4.5 sun hours and 20% losses that is about 1.44 kWh a day, or roughly 44 kWh in an average month.
What size solar system do I need?
Divide your daily use by peak sun hours times 0.8. A home using 900 kWh a month uses about 29.6 kWh a day; at 4.5 sun hours that needs about 8.22 kW, which rounds to 21 panels of 400 W (8.4 kW).
How much roof space do 20 solar panels need?
Common 400–450 W panels are about 21 sq ft (1.95 m²) each, so 20 panels cover about 420 sq ft (39 m²) before the setbacks and access paths your local code requires.