Dry winter air comes from outside. Cold air holds very little water, and as it leaks in and warms up, its relative humidity drops to desert levels. A humidifier has to replace that missing water, which is why a drafty house needs a much bigger one than a tight house of the same size.
How the calculator works
It estimates how much outdoor air comes in, how much water each pound of that air is missing, and multiplies:
air in per hour (cu ft) = floor area × ceiling height × air changes per hour
water per hour (lb) = air in × 0.075 lb per cu ft × (indoor humidity ratio − outdoor humidity ratio)
gallons per day = water per hour × 24 ÷ 8.34
The humidity ratio is the weight of water vapor per pound of dry air, figured at 70 °F indoors and at your chosen outdoor temperature with 70 percent relative humidity outside.
Worked example: a 2,000 sq ft house on a 20 °F day
The house has 8 ft ceilings and average construction, and the owners want 40 percent indoor humidity.
- Air volume: 2,000 × 8 = 16,000 cu ft. At 0.5 air changes per hour, 8,000 cu ft of outdoor air comes in every hour.
- Air at 70 °F and 40 percent holds about 43 grains of water per pound; outdoor air at 20 °F holds about 10. Each pound is short by 32.9 grains (7,000 grains make a pound).
- Water per hour: 8,000 × 0.075 × 32.9 ÷ 7,000 = 2.82 lb.
- Per day: 2.82 × 24 ÷ 8.34 = 8.1 gallons, about 30.7 liters.
A portable unit with a 1.5 gallon tank would need refilling about 5.4 times a day, which is why houses this size usually get a whole-house humidifier on the furnace or a large console unit.
Humidifier size chart by square feet
Gallons per day at 40 percent indoor humidity on a 20 °F day, with 8 ft ceilings. Compare these with the daily output listed on the box or spec sheet, not the square footage claim alone.
| House size | Tight | Average | Older or leaky | Very drafty |
|---|---|---|---|---|
| 1,000 sq ft (93 m²) | 2.8 | 4.1 | 6.1 | 8.1 |
| 1,500 sq ft (139 m²) | 4.3 | 6.1 | 9.1 | 12.2 |
| 2,000 sq ft (186 m²) | 5.7 | 8.1 | 12.2 | 16.2 |
| 2,500 sq ft (232 m²) | 7.1 | 10.1 | 15.2 | 20.3 |
| 3,000 sq ft (279 m²) | 8.5 | 12.2 | 18.3 | 24.3 |
The leakiest house needs nearly three times what the tightest one does. Sealing drafts first, with the weather stripping calculator, often shrinks the humidifier you need and your heating bill too; the heat loss calculator uses the same air-change idea for heat.
Colder weather, lower humidity target
In very cold weather, humid indoor air condenses on cold window glass. A widely used rule of thumb lowers the indoor target as the temperature falls, which keeps the water needed fairly steady for the same 2,000 sq ft house:
| Outdoor temperature | Suggested maximum indoor humidity | Gallons per day at that level |
|---|---|---|
| 20 °F (−7 °C) and above | 40% | 8.1 at 20 °F |
| 10 °F (−12 °C) | 35% | 7.8 |
| 0 °F (−18 °C) | 30% | 7.1 |
| −10 °F (−23 °C) | 25% | 6.1 |
| −20 °F (−29 °C) | 20% | 5 |
Size for a typical cold day at the target you will really use. If water or frost forms on the inside of the glass, turn it down. Our guide to the ideal indoor humidity in winter explains why the safe level falls as the weather gets colder.
Sizing for one room
For a bedroom, enter only its floor area. A 12 × 12 ft room comes out at about 0.6 gallons a day, but air moves under doors and through returns, so choose a unit with output comfortably above that and check with a hygrometer. The square footage calculator helps with odd shapes.
Practical tips
- Pick a unit with a built-in humidistat, or set the furnace humidifier's control, so it shuts off at the target instead of running flat out.
- Furnace-mounted humidifiers only add water while the blower runs, so check their rated output against the result.
- Electric steam units use far more power than evaporative ones. The electricity cost calculator turns the label watts into a monthly cost.
Safety and health notes
- More is not better. The EPA recommends keeping indoor humidity between 30 and 50 percent; above that, mold, dust mites and rot in walls and attics become a risk.
- Empty, rinse and dry portable tanks often and clean them as the manufacturer directs; standing water grows bacteria and mold that the unit then sprays into the room.
- Warm-mist and steam units can scald. Keep them out of children's reach and away from bedding and curtains.
- A whole-house humidifier involves a water line, a drain and wiring to the furnace. Hire a licensed contractor if you are not comfortable with that work, and check local plumbing and electrical code.
Frequently asked questions
What size humidifier do I need for 2,000 square feet?
About 8.1 gallons per day for an average house on a 20 °F day at 40 percent indoor humidity. A tight, newer house needs about 5.7 gallons a day and an older, leaky one about 12.2.
Why does my humidifier not keep up?
Usually because the house leaks more outdoor air than the humidifier was sized for. The same 2,000 sq ft house needs 8.1 gallons a day with average sealing but 16.2 if it is very drafty. Sealing drafts or lowering the target from 40 to 30 percent (5.4 gallons a day) closes the gap.
Can a humidifier be too big?
A unit with more output than you need is fine if a humidistat shuts it off at the target. Without one it can push humidity past 50 percent, which leads to window condensation, mold and dust mites.
How many gallons a day for 1,500 square feet?
About 6.1 gallons a day for average construction on a 20 °F day at 40 percent. An older, leaky 1,500 sq ft house at 0 °F, held at the suggested 30 percent, needs about 7.9.