How the calculator works
Weatherstrip goes wherever a moving part meets a fixed frame. On a hinged door that is the two side jambs and the head jamb; the bottom gap gets a door sweep or threshold seal instead. On a window it is the edges of each sash, plus the spot in the middle where two sashes meet.
door (in) = 2 × height + width
window (in) = 2 × (width + height) + meeting rail (width) or meeting stiles (height)
to buy = (doors + windows + other openings) × (1 + waste %)
Divide inches by 12 for feet. A waste allowance of 5 to 10 percent is the common recommendation, because you lose a few inches at every corner and every restart. The calculator then splits the result into the door part (often bought as a jamb kit) and the window part (usually bought in rolls), since the two rarely use the same product.
Worked example
A house has two 36 × 80 in entry doors and six double-hung windows, each 30 in wide and 48 in tall. You plan to use foam tape sold in 17 ft rolls and add 10 percent for waste.
| Item | Math | Length |
|---|---|---|
| Each door | 2 × 80 + 36 = 196 in | 16.3 ft |
| Each window | 2 × (30 + 48) + 30 = 186 in | 15.5 ft |
| 2 doors | 2 × 196 in | 32.7 ft |
| 6 windows | 6 × 186 in | 93 ft |
| Total before waste | 125.7 ft | |
| With 10% extra | 125.7 × 1.10 | 139 ft |
Split up, that is 36 ft (or two door kits) for the doors and 103 ft for the windows. At 17 ft per roll, 103 ÷ 17 = 6.06, so buy 7 rolls for the windows, plus 2 door sweeps at least 36 in long. In metric, the whole job is about 42.2 m.
How to measure for weather stripping
- Doors: measure the opening inside the jambs, not the door slab. Most US entry doors are 36 in wide and 80 in tall, but older homes and side doors are often 30 or 32 in.
- Windows: measure the sash, the part that moves. For a hung window, enter the sash width and the full height of the window; the calculator adds the meeting rail where the two sashes overlap.
- Sliders: a sliding window or patio door has a vertical meeting stile where the panels overlap, so its height is added once.
- Other openings: add the perimeter of the attic hatch, a basement or garage entry door, or a crawlspace access panel. A 22 × 30 in hatch, the minimum attic access size in the International Residential Code, has a perimeter of 104 in, about 8.7 ft.
To find the size of the gap, close the door or window on a strip of paper. If it slides out with no drag, the seal is weak there. Pick a product slightly thicker than the gap so it compresses when closed. For drafty single-pane glass that weatherstrip alone cannot fix, see the window insulation film calculator.
Which type of weatherstrip to use where
| Type | Best for | Notes |
|---|---|---|
| Adhesive foam tape | Window sashes, attic hatches, irregular gaps | Cheap and fast; compresses and wears out sooner than other types |
| V-strip (tension seal) | Sides of hung and sliding sashes, door jambs | Seals by springing open; hidden once installed |
| Tubular rubber, vinyl or silicone | Door jambs, larger or uneven gaps | Durable; the visible edge may need trimming to look tidy |
| Kerf-in foam or bulb | Newer prehung doors with a slot in the jamb | Pull the old strip out and press the new one into the slot |
| Felt | Low-traffic spots | Inexpensive but wears fastest; not for wet areas |
| Door sweep or threshold gasket | Bottom of exterior doors | One per door; cut to the door width |
Tips for a seal that lasts
- Clean the surface first and apply adhesive products only when the frame is dry and at or above the minimum application temperature printed on the package. Adhesives grab poorly on a frosty frame, so on a cold day let the indoor heat warm the frame first.
- Run strips in one continuous piece along each side and butt them tightly at corners. Small gaps at corners undo much of the work.
- Make sure the door still latches and the window still locks. If you have to force it, the strip is too thick.
- Weatherstripping stops air moving around the sash; it does nothing for heat moving through the glass or walls. To see how much air leaks matter in a room, try the heat loss calculator, and for the attic side, the insulation calculator.
- Seal the crawlspace hatch and gaps near plumbing too; drafts there are a common reason pipes freeze.
- Less cold air sneaking in also means drier winter air is easier to fix: the humidifier size calculator shows how much less water a humidifier has to add once a house is better sealed.
Safety notes
- Never seal a bedroom egress window or an exit door so it is hard to open. Use compressible strips, not caulk or paint, on anything that has to open.
- Homes with gas, oil or wood-burning appliances need combustion air. After sealing a lot of leaks, have the venting checked, and keep carbon monoxide alarms working.
- Paint on windows in US homes built before 1978 may contain lead. Do not sand or scrape it dry; follow lead-safe practices or hire a certified renovator.
Frequently asked questions
How much weather stripping do I need for a door?
For a standard 36 × 80 in door, seal both sides and the top: 2 × 80 + 36 = 196 in, about 16.3 ft. With 10 percent extra, buy 18 ft, or one door jamb kit, plus a sweep at least 36 in long for the bottom.
How many feet of weatherstrip does a window need?
Measure the sash perimeter and add the meeting rail on a hung window. A 24 × 36 in casement needs 10 ft, the same size double-hung needs 12 ft, and a 60 in wide by 36 in tall slider needs 19 ft before waste.
How do I know what thickness to buy?
Close the door or window on a strip of paper to find loose spots, then choose a product slightly thicker than the gap so it compresses. If the door will not latch afterward, it is too thick.
Should I weatherstrip the attic hatch?
Yes. It is one of the leakiest spots in many homes. A 22 × 30 in hatch needs about 8.7 ft of foam or bulb strip around its edge; add rigid foam insulation to the back of the panel too.