Size a water heater for your busiest hour, not your house
A tank water heater rarely runs out on an average day. It runs out on the morning when three people shower back to back while the washer fills. That is why sizing starts with peak-hour demand: the gallons of hot water your household pulls in its single busiest hour. Square footage and bathroom count are only rough stand-ins for that number.
Tank heaters are compared by their first-hour rating (FHR), printed as "Capacity (first hour rating)" on the yellow EnergyGuide label. It is how many gallons of hot water the heater can deliver in one hour starting with a full, hot tank. Pick a model whose FHR is at least your peak-hour demand. Tank capacity alone does not tell you this, because a heater with a strong burner recovers faster than one with a weak element.
How the calculator works
You do not shower in 120°F water. A shower or bath is mixed to roughly 105°F, so part of what comes out of the head is cold water. The share drawn from the heater is:
hot share = (105°F − cold inlet temperature) ÷ (heater setting − cold inlet temperature)
shower hot water (gal) = showers × flow (gpm) × minutes × hot share
Washers, dishwashers and sink uses are counted as all hot water at their rule-of-thumb volumes, then everything is added up. For tankless units the calculator takes the showers you expect to run at once, converts them to hot water flow, and finds the heat output from the temperature rise:
output (BTU/hr) ≈ 500 × hot flow (gpm) × (setting − inlet temperature)
The 500 comes from 8.33 lb per gallon × 60 minutes; divide BTU/hr by 3,412 for kilowatts.
Worked example: a family of four on a weekday morning
Three people take 8-minute showers with 2.0 gpm heads, one person runs a front-load washer on warm, and someone rinses breakfast dishes in the sink. Winter supply water is 50°F and the heater is set to 120°F.
| Use | Math | Hot water |
|---|---|---|
| Hot share for showers | (105 − 50) ÷ (120 − 50) | 79% |
| Showers | 3 × 2.0 × 8 × 0.786 | 37.7 gal |
| Front-load washer | 1 load | 15 gal |
| Kitchen sink | 1 use | 3 gal |
| Peak hour | 55.7 gal (211 L) |
Look for a tank with a first-hour rating of 56 gallons or more. If two of those showers overlap, a tankless unit would need to supply 3.14 gpm of 120°F water at a 70°F rise, about 110,000 BTU/hr of output (32.2 kW).
Now change one thing at a time. With 2.5 gpm heads the hour climbs to 65.1 gal. With 1.8 gpm heads it drops to 51.9 gal. With 40°F winter water it rises to 57 gal, and the tankless figure jumps to 3.25 gpm at an 80°F rise, about 130,000 BTU/hr. Cold groundwater hurts tankless units most, so size them for January, not July.
Typical peak hours by household size
These rows are examples built with the same assumptions (8-minute, 2.0 gpm showers, 50°F water, 120°F setting, one sink use). Your own busiest hour may look different, so enter it rather than relying on head count.
| Household | Example busiest hour | Peak-hour demand |
|---|---|---|
| 1–2 people | 2 showers | 28.1 gal |
| 3 people | 3 showers | 40.7 gal |
| 4 people | 3 showers + front-load wash | 55.7 gal |
| 5 people | 4 showers + front-load wash | 68.3 gal |
| 6 people | 5 showers + top-load wash | 90.9 gal |
Tips before you buy
- Find your real busiest hour. For many families it is the weekday morning; for others it is a Sunday evening with baths and laundry. Moving laundry or the dishwasher out of that hour can drop you a full size.
- Read the EnergyGuide label. Gas tanks usually have a first-hour rating above their gallon size because the burner reheats quickly; electric tanks generally rate lower than gas models of the same size. Heat pump water heaters list FHR in the maker's literature, and recovery can be slower in their efficiency-only mode.
- A big soaking tub changes the answer. One 40 gal bath at a 79% hot share pulls about 31 gal from the heater. Make sure the tank can fill it with hot water to spare.
- Bigger is not free. An oversized tank keeps extra water hot around the clock. Check standby losses and running cost with the electricity cost calculator, and if you plan to back the heater up during outages, add it to the generator wattage calculator.
- Protect the pipes, too. A heater in a garage or crawlspace and the lines feeding it can freeze; see how to keep pipes from freezing.
Safety and code notes
- A 120°F setting is the common US recommendation for limiting scalds. Hotter storage helps control bacteria, and some places require it: in Australia, storage heaters are typically kept at 60 °C or more with delivery to bathrooms limited to about 50 °C by a tempering valve. If you store water hot, install anti-scald mixing valves.
- Gas heaters need proper venting, combustion air and gas connections. Keep carbon monoxide alarms working and use a licensed installer where required.
- Every tank needs a working temperature and pressure relief valve piped to a safe spot. Many areas also require an expansion tank, seismic strapping or a drain pan.
- Replacing a water heater usually needs a permit. Electric and tankless units may need a larger breaker or new wiring; tankless gas units often need a bigger gas line. Check local code before you buy.
Frequently asked questions
What size water heater do I need for a family of 4?
Base it on your busiest hour. Three 8-minute, 2.0 gpm showers plus a front-load wash and one sink use come to about 55.7 gallons of hot water at a 120°F setting with 50°F supply water, so look for a first-hour rating of at least 56 gallons.
What is a first-hour rating?
It is the number of gallons of hot water a tank heater can supply in one hour starting full and hot. It is printed on the EnergyGuide label as Capacity (first hour rating). Choose a model whose rating at least matches your peak-hour demand.
How many gallons of hot water does a shower use?
Multiply flow by minutes and by the hot share. An 8-minute shower with a 2.0 gpm head uses 16 gallons of mixed water; with 50°F supply water and a 120°F setting, about 79% of it, or 12.6 gallons, comes from the heater.
What size tankless water heater do I need for two showers?
Two 2.0 gpm showers need about 3.14 gpm of 120°F water when the supply is 50°F, a 70°F rise, or about 110,000 BTU/hr of output. With 40°F winter water it is 3.25 gpm at an 80°F rise, about 130,000 BTU/hr.